Turbo-expander unit MTDA-1.2-3.2-MP-U2. “Mashevka” complex gas treatment plant. Since 2009

Turbo-expander unit MTDA-1.2-3.2-MP-U2. “Mashevka” complex gas treatment plant. Since 2009

Gas cons., mln. m³/d 1,2÷0,76
Shaft power, kW 185
Start year 2009
Nuber of units 1
Rotor bearing type AMB*
Expander Pin, MPa 3,2
Pout, MPa 2,56
Тin, °С -17÷-15
Тout, °С -29÷-25
DNin, mm 200
DNout, mm 300
Compressor Pin, MPa 2,5÷2,3
Pout, MPa 2,8÷2,6
Тin, °С 1÷30
Тout, °С 10÷40
DNin, mm 300
DNout, mm 300

*) AMB-Active Magnetic Bearing